Old May 10th, 2009, 05:26 AM   #1 (permalink)
rmattich
 
Join Date: Aug 2008
Posts: 10
rmattich is on a distinguished road
telco out pulse change

We have a PRI circuit for our local numbers. The telco has been out pulsing 3 digits to us. I have been using the inc-call-handling-trmt table to change the numbers to a 4 digit extension. We are moving some more numbers to that trunk and due to overlapping of the last 3 digits, I have had the telco out pulse the 7 digit number. They said that they have completed the order and have gone back at my request to verify that it was indeed completed. However, I am still seeing only 3 digits when I do a trace on the tac. The circuit terminates on a TN464 card and we have an Avaya S8500 switch running CM4. Before I had the change made, I added the 7 digit number in the table. After we were supposed to be getting 7, I deleted the 3 digit entry and the call is not routed according to the 7 digit entry.
Is there something that I need to configure on the Avaya side to look for 7 digits on an incoming call?
Here’s a sample trace:
16:07:04 Calling party trunk-group 6 member 1 cid 0x389d
16:07:04 Calling Number & Name xxxxxxxxxx NO-CPName
16:07:04 active trunk-group 6 member 1 cid 0x389d
16:07:04 dial 728#
16:07:04 term trunk-group 6 cid 0x389d
16:07:04 term attendant-group 1 cid 0x389d
16:07:04 dial 0
16:07:04 ring attendant-group 1 cid 0x389d
16:07:07 active attendant 3105 cid 0x389d
rmattich is offline   Reply With Quote
Old May 11th, 2009, 12:27 PM   #2 (permalink)
martinyoung
Moderator
 
martinyoung's Avatar
 
Join Date: Dec 2005
Posts: 1,664
martinyoung will become famous soon enoughmartinyoung will become famous soon enough
Re: telco out pulse change

If the trace on the TAC does not show 7 digits, then you are not getting 7 digits. This is incoming data before it gets to the PBX.

Once you are getting 7 digits you need to update your dialplan, vectors, VDNs, announcements, stations, etc to reflect this.
__________________
Marty
Retired Avaya DSIC tech
martinyoung is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old May 11th, 2009, 12:30 PM   #3 (permalink)
rmattich
 
Join Date: Aug 2008
Posts: 10
rmattich is on a distinguished road
Re: telco out pulse change

ok, thanks for the reply. I just wasn't sure where to start. The telco states that they are sending 7 digits but the trace only shows 3. I wasn't sure if I had to make a change on the Avaya side to check for more digits but from what you say, the trace reads the raw data directly from the D-channel.
rmattich is offline   Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -6. The time now is 12:30 PM.


Powered by vBulletin® Version 3.8.1
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC6
Copyright ©2002 - 2007, PBXtech LLCAd Management by RedTyger

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39