#1 (permalink) |
![]() Join Date: Aug 2003
Posts: 3
![]() |
My first time posting. Was wondering if anyone here has come across the following problem. Our megalink is down right now with Alarm Status "waiting"
The D channel is disabled and I think it's because the clocking is not right. It is "free running" and I believe should be clocking from loop 2 Would anyone be able to view the output below and determine a course of action for activating the clock. Any effor would be much appreciated. Jason ************************************ stat 2 PRI* TRK LOOP 2 - ENBL FFMT/LCMT/YALMT: ESF/B8Z/FDL SERVICE RESTORE: YES YEL ALM PROCESS: YES ALARM STATUS : WAITING CH 01 - IDLE ISA CH 02 - IDLE ISA CH 03 - IDLE ISA CH 04 - IDLE ISA CH 05 - IDLE ISA CH 06 - IDLE ISA CH 07 - IDLE ISA CH 08 - IDLE ISA CH 09 - IDLE ISA CH 10 - IDLE ISA CH 11 - IDLE ISA CH 12 - IDLE ISA CH 13 - IDLE ISA CH 14 - IDLE ISA CH 15 - IDLE ISA CH 16 - IDLE ISA CH 17 - IDLE ISA CH 18 - IDLE ISA CH 19 - IDLE ISA CH 20 - IDLE ISA CH 21 - IDLE ISA CH 22 - IDLE ISA CH 23 - IDLE ISA CH 24 - DCH 63 . DTC016 ssck 0 ENBL CLOCK ACTIVE SYSTEM CLOCK - DTI061 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL REF CLK ERR .**** OVL000 >ld 96 DCH000 .stat dch DCH 63 : DSBL RST AUTO DES : MEGA .en DCH009 .est dch 63 . DCH1019 63 002CD829 00000003 stat dch DCH 63 : DSBL RST AUTO DES : MEGA .ench dch DCH009 .en DCH009 .ench * DCH000 .enl dch 63 .stat 2 DCH010 .stat dch DCH 63 : OPER AEST AUTO DES : MEGA . DCH: 63 RLS NO RESPONSE TIME: 6:57:36 16/08/2003 stat dch DCH 63 : OPER RLS AUTO DES : MEGA .**** OVL000 >ld 60 DTI000 .ssck 0 ENBL CLOCK ACTIVE SYSTEM CLOCK - DTI061 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL REF CLK ERR .trck pclk DTI054 .ssck 0 ENBL CLOCK ACTIVE SYSTEM CLOCK - DTI061 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL REF CLK ERR . TIM1993 07:00 16/8/2003 CPU 0 DTI000 .**** OVL000 >ld 60 DTI000 .ench DTI003 .enck 2 DTI002 .ssck 0 ENBL CLOCK ACTIVE SYSTEM CLOCK - DTI061 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL REF CLK ERR .dsck 2 DTI002 .dis cc 0 DTI002 .enl cc 0 DTI067 .ssck 0 ENBL CLOCK ACTIVE SYSTEM CLOCK - DTI061 PREF - 2 SREF - FREE RUN AUTO SWREF CLK - ENBL REF CLK ERR . |
|
|
|
|
|
#2 (permalink) |
|
Moderator
![]() Join Date: Jul 2003
Posts: 159
![]() |
Jason,
Clocking looks O.K., The first problem I see is the alarm status should read (no alarm) or Red alarm which means the switch does not see the T-1. I would recommend you check T-1 circiut or put a loop back on the csu until the alarm status reads no alarm. That will most likely clear other problems. Let me know ![]() |
|
|
|
| Sponsored links | |
|
Advertisement
|
|
|
|
#3 (permalink) |
![]() Join Date: Aug 2003
Posts: 3
![]() |
Thanks very much, however all is OK now. I ended up calling Telus and they determined our dual line PRI card was blown. After reaplacement it responded right away to the enabling of loop 2 and that was that, back in business. What upset us was the cost $7000.00 for the card which we had to pay being on time and material -- having terminated our service contract only a couple months previously after years of paying the fees.
thanks again. |
|
|
|
|
|
#4 (permalink) |
|
PBXtech GOLD 100+ posts
![]() Join Date: Jun 2003
Posts: 132
![]() |
In the future you may want to check out some companies for refurbished parts. i have had great success with some of these parts. I recently bought some cards for $60. which our vendor wanted $1267.00 for the same card. Or have found a hard drive for the Meridian Mail system for $200 that our vendor wanted over $2,000 for. Let me know if you want some contacts for the future.
|
|
|
|
|
|
#6 (permalink) |
![]() Join Date: Apr 2004
Posts: 11
![]() |
Re: No clocking on PRI loop
Jason
It sounds like the solution to the problem is in hand. However I would be concerned about the message: SYSTEM CLOCK - DTI061 It may be that you were getting it due to bad signal from your dual loop PRI card to the clock controller due to the bad dual loop PRI card or you still may have a problem with your clock controller card. I don't know if you are using a QPC471 clock control card. If you are I find that sometimes disabling and reseating the card then re-enabling clears the problem. Also check your cables from the faceplate of the PRI card to the 471 pack. |
|
|
|
|
Advertisement
|
Sponsored links
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| PRI setup assistance | nfarooqui | Definity Servers | 6 | August 23rd, 2005 05:25 PM |
| Canceling PRI. Need to change sync? | liquidvw | Definity Servers | 2 | August 3rd, 2005 08:13 AM |
| Splitting PRI Channels for Fax Sever. Newbie. Help.. | hboogz | Merlin Systems | 1 | February 22nd, 2005 06:11 PM |
| PRI Printout on Option 61 / RDB and TNB | mtfs | Meridian systems | 0 | July 4th, 2003 04:54 PM |
| How do you set which T1 or PRI for clocking? | mtfs | Definity Servers | 1 | June 8th, 2003 11:03 PM |