PBXtech.info  
\'\'

Go Back   PBXtech.info > Nortel > Meridian systems

Reply
 
LinkBack Thread Tools Display Modes
Old September 5th, 2008, 02:43 PM   #1 (permalink)
EddardStark
 
Join Date: Jan 2008
Posts: 6
EddardStark is on a distinguished road
Option 11c - Check version

I'm hoping this is an easy request. I just want to check my OS version. What syntax or load command do I need to use? Thanks.
EddardStark is offline   Reply With Quote
Old September 8th, 2008, 04:37 PM   #2 (permalink)
Fletch
 
Fletch's Avatar
 
Join Date: Sep 2008
Posts: 11
Fletch is on a distinguished road
Re: Option 11c - Check version

TO check the VxWorks OS system level, you need to be in PDT mode on the system. PDT commands are not generally discussed openly on public boards.
__________________
Fletch
Nortel E911 PLM
Visit Nortel onthe web at http://nortel.com/e911

Be sure to attend the FREE E911 webinar on Oct. 30th
Register at http://thevoicereport.com/E911
Fletch is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old September 9th, 2008, 08:25 AM   #3 (permalink)
EddardStark
 
Join Date: Jan 2008
Posts: 6
EddardStark is on a distinguished road
Re: Option 11c - Check version

Wow. So there is no easy way to check something as simple as OS rev while on a terminal directly connected to the PBX? That seems a little silly.
EddardStark is offline   Reply With Quote
Old September 9th, 2008, 08:56 AM   #4 (permalink)
Fletch
 
Fletch's Avatar
 
Join Date: Sep 2008
Posts: 11
Fletch is on a distinguished road
Re: Option 11c - Check version

The OS version of VxWorks is packaged with the version of CS 1000 software. So, if you have Version xx.xx of the CS 1000, you have Version yy.yy of VxWorks.

You cannot pick the OS version that you run on. You can only choose the CS 1000 Software release.

Given this, there is really no need to ever look up that VxWorks OS version information, so there is no need to dip into the PDT CLI to get it.

For a Release 5.50 system this information is:

VxWorks (for CP PM - Pentium M 1.4 GHz) version 5.5.1.
Kernel: WIND version 2.6.
__________________
Fletch
Nortel E911 PLM
Visit Nortel onthe web at http://nortel.com/e911

Be sure to attend the FREE E911 webinar on Oct. 30th
Register at http://thevoicereport.com/E911
Fletch is offline   Reply With Quote
Old September 9th, 2008, 09:59 AM   #5 (permalink)
EddardStark
 
Join Date: Jan 2008
Posts: 6
EddardStark is on a distinguished road
Re: Option 11c - Check version

How can I find the CS 1000 software release version then? My company was bought out and as part of the discovery phase, the purchaser is attempting to find out this information.
EddardStark is offline   Reply With Quote
Old September 9th, 2008, 10:02 AM   #6 (permalink)
Fletch
 
Fletch's Avatar
 
Join Date: Sep 2008
Posts: 11
Fletch is on a distinguished road
Re: Option 11c - Check version

Code:
 
LD 22
 
REQ ISS
 
VERSION 4021
System type is - Communication Server 1000E/CP PM
CP PM - Pentium M 1.4 GHz
IPMGs Registered:               1
IPMGs Unregistered:             0
IPMGs Configured/unregistered:  0
RELEASE 5
ISSUE 50 J  +
 
IDLE_SET_DISPLAY CS1000E R5.50J System A
 
IPMG  TYPE CSP/SW MSP  APP  FPGA BOOT   DBL1     DBL2
  4 0 MGC    AH14 AA06 AA05 AA13 AH09 DSP1AA09      N/A
 
REQ
__________________
Fletch
Nortel E911 PLM
Visit Nortel onthe web at http://nortel.com/e911

Be sure to attend the FREE E911 webinar on Oct. 30th
Register at http://thevoicereport.com/E911
Fletch is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old September 9th, 2008, 01:39 PM   #7 (permalink)
EddardStark
 
Join Date: Jan 2008
Posts: 6
EddardStark is on a distinguished road
Re: Option 11c - Check version

Excellent. Thanks.
EddardStark is offline   Reply With Quote
Old September 10th, 2008, 11:22 PM   #8 (permalink)
westcoaster
 
Join Date: Jul 2008
Posts: 21
westcoaster will become famous soon enough
Re: Option 11c - Check version

The other thing they may want are the system limits (how many software licenses etc.)


ld 22

REQ SLT
westcoaster is offline   Reply With Quote
Old September 11th, 2008, 07:07 AM   #9 (permalink)
Fletch
 
Fletch's Avatar
 
Join Date: Sep 2008
Posts: 11
Fletch is on a distinguished road
Re: Option 11c - Check version

And if you are going that far, you might as well run the inventory reports in LD 117 as well.

Code:
 
>ld 117
OAM000
=> inv gen all
Generate card, set & locrpt inventory
Started successfully
=>
MAT052 Inventory locrpt generation complete
 
MAT011 Inventory sets generation complete
 
MAT010 Inventory card generation complete
Wait for the reports to complete, then you can print them.

Code:
 
=> inv prt all
ALL (Card, Set & Locrpt Inventory)
Card inventory:
11 9 2008 8 3 45, 11 9 2008 8 4 32, 19
XCT-TDS/MF, 0, <Unavailable>
CONF, 1, <Unavailable>
TMDI, 8, NTRB21AC
TMDI, 9, NTRB21AA
XCT-TDS/MF, 16, <Unavailable>
CONF, 17, <Unavailable>
XCT-TDS/MF, 60, <Unavailable>
CONF, 61, <Unavailable>
MGC , 004 0, NTDW60BA 3 NNTMG19Y3274
ISP1100 SS, 0 0 0, NTDU27xx NNTMxxxxxxx, CS1K201-2, 192.168.200.6
CP-PM CS 0, 4 0 1, NTDW61BAE5 3 NNTMG19Y36
CPPM SS, 4 0 2, NTDW61BAE50003 NNTMG19Y63VACPP, CS1K201, 192.168.200.5
XUT , 004 0 03, NT8D14CB 01 NNTMENC7TEYF 0745
DLC , 004 0 04, NT8D02HA 01 NNTMENC7W59V 0751
500 , 004 0 05, NT8D09CA 04 NNTMENC7V3GW 0747
DLC , 004 0 06, NT8D02EA 0300TZ00000000000000000
DSPDB , 004 0 11, NTDW64AA R01 NNTMG19Y2Y45
DSPDB , 004 0 12, <Unavailable>
DSPDB , 004 0 13, <Unavailable>
DTR , 004 0 14, <Unavailable>
MFR , 004 0 15, <Unavailable>
Sets inventory:
11 9 2008 8 3 45, 11 9 2008 8 3 54, 980
3904, 004 0 04 01, M3904 NTMN03EC 70 01 3BEA0E , PBX201, 6302
2616, 004 0 04 02, <Unavailable>, PBX201, 6202
3905, 004 0 04 05, M3905 NTMN06BA 70 12 CADA58 , PBX201, 2911002
2616, 004 0 06 01, M2616 NT9K16AC 03 04 F66A03 , PBX201, 6301
1140, 096 0 00 00, <Unavailable>, PBX201, 6694
2210, 096 0 00 01, <Unavailable>, PBX201, 6150
2004P2, 096 0 00 02, 2004P2 NTDU92AA 66 2 E52731 , PBX201, 6102
2004P2, 096 0 00 03, 2004P2 NTDU92AA 66 2 F493CD , PBX201, 6134
1140, 096 0 00 04, 1140 NTYS05AA 66 25 2F52C3 , PBX201, 6100
KEM1, 096 0 00 04, NGKem NTYS08AA 1 4D4547
KEM2, 096 0 00 04, NGKem NTYS08AA 1 4D4547
KEM3, 096 0 00 04, 000000
2002P2, 096 0 00 05, 2002P2 NTDU91AA 66 2 FAE620 , PBX201, 6111
1140, 096 0 00 06, <Unavailable>, PBX201, 6695
2004P1, 096 0 00 07, 2004P1 NT2K00GI 66 0 76DE40 , PBX201, 6131
2004P2, 096 0 00 08, 2004P2 NTDU92AA 66 2 F49462 , PBX201, 6201
1110, 096 0 00 09, <Unavailable>, PBX201, 6160
1140, 096 0 00 10, <Unavailable>, PBX201, 6696
1140, 096 0 00 11, <Unavailable>, PBX201, 6697
2001P2, 096 0 00 12, 2001P2 NTDU90AA 66 2 E5E1A8 , PBX201, 6113
1140, 096 0 00 13, <Unavailable>, PBX201, 6698
2001P2, 096 0 00 14, 2001P2 NTDU90AA 66 2 E5E154 , PBX201, 6101
2002P2, 096 0 00 15, 2002P2 NTDU91AA 66 2 FAE61C , PBX201, 6133
2004P1, 096 0 00 16, 2004P1 NT2K00GI 66 0 050796 , PBX201, 6116
2050PC, 096 0 00 17, <Unavailable>, PBX201, 6117
2210, 096 0 00 18, 2210 NTTQ4021 66 12 06D9D5 , PBX201, 6218
2210, 096 0 00 19, 2210 NTTQ4020 66 11 068704 , PBX201, 6219
2210, 096 0 00 20, <Unavailable>, PBX201, 6220
1140, 096 0 00 21, <Unavailable>, PBX201, 6699
1140, 096 0 00 22, <Unavailable>, PBX201, 6988
1140, 096 0 00 23, <Unavailable>, PBX201, 6989
__________________
Fletch
Nortel E911 PLM
Visit Nortel onthe web at http://nortel.com/e911

Be sure to attend the FREE E911 webinar on Oct. 30th
Register at http://thevoicereport.com/E911
Fletch is offline   Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


All times are GMT -6. The time now is 11:13 PM.


Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC6
Copyright ©2002 - 2007, PBXtech LLCAd Management by RedTyger