#1 (permalink) |
![]() Join Date: Dec 2006
Posts: 8
![]() |
System monitor not responding (STAT XSM)
Hi friends,
we are using meridian 1 option 61c with rel 24.25 i have a problem with my System Monitor ( NT8D22 ) When i try get the status of System monitor using LD 37 STAT XSM it is giving the message IOD300 0 . . i.e., No response received from System Monitor ( NT8D22 ) after sending status request. Before getting this message i tried to connect the TTY 7 to RS-232 port of my PC after that i got these errors IOD318 7 ERR225 0 7 ERR225 0 7 IOD319 7 please can anybody help me in this regard. Thank you for your time. |
|
|
|
|
|
#2 (permalink) |
![]() Join Date: Jun 2006
Posts: 2
![]() |
Re: System monitor not responding (STAT XSM)
Hi
I had the same problem a few weeks ago. I disabled the sys mon enabled it and it was the same. I reseated the sys mon card and it was fine after that. Allan |
|
|
|
|
Advertisement
|
Sponsored links
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
|
|