#1 (permalink) |
|
Registered User
Join Date: Jan 2004
Posts: 27
![]() |
the big boss has had a revelation; the receptionist area (which has been in place longer then I’ve been alive) is in the wrong part of the office, and must be moved before OCT 1st.
skipping the long convoluted argument with the site liaison, the end result is i need to understand the pin out of the SL-1 card and the M1250 attendant console. here is the ATT record from LD 20: TN 017 0 08 00 TYPE 1250 CDEN DD CUST 0 SGRP 0 SETN 017 0 08 01 ANUM 01 ALPD NO SSU ICDR ICDD ABAN ABDD CPND CNDA AADN DNDI DNDD KEY 00 BVR KEY 01 BIN KEY 02 DCW KEY 03 DPD KEY 04 DPS KEY 05 PAG 700 KEY 06 PAG 710 KEY 07 PRK KEY 08 ADL 4*250458 KEY 09 ADL DATE 22 DEC 1999 TN 017 0 08 02 TYPE PWR CDEN DD DATE 30 JUL 2001 TN 017 0 08 03 TYPE PWR CDEN DD DATE 30 JUL 2001 this looks like 4 pair: 2 power (17 0 8 2 & 3) and 2 data (17 0 8 0 & 1) can anyone help me translate this into the DB25F that connects to the back of the M1250 console? |
|
|
|
|
|
#2 (permalink) |
![]() Join Date: Oct 2004
Posts: 2
![]() |
Re: wiring of the 1250 console
It's for a M2250 and a CIU . should be the same for a M1250.
On D25 connector. The first TN must be on pin 14 (+) and 2 (-) The second TN must be on pin 15 (+)and 3 (-) The PWR (+) on pin 17 and 5 and (-) on pin 18 and 6 Last edited by TimG; October 11th, 2004 at 03:07 AM. |
|
|
|
|
Advertisement
|
Sponsored links
|
|
|
#3 (permalink) | |
|
Registered User
Join Date: Jan 2004
Posts: 27
![]() |
Quote:
i managed to find the pinnout to the centronix 50pin and just before the deadline, but they decided to change plans at the last second. however, with this and the engineering guide part 3 i can document the centronix 50 to DB25f cable in the event it ever needs to be replaced, which might be soon, considering it's been wheelee-chaired a few thousand times. |
|
|
|
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Can a 2420 be used as a console? | zooney9334 | Definity Servers | 5 | August 7th, 2007 07:34 PM |
| Console Headset | Earwig | Definity Servers | 2 | December 8th, 2005 04:08 PM |
| Console Question | Earwig | Definity Servers | 1 | October 12th, 2005 12:32 PM |
| console to console call transfer problem | pravinfarad | Meridian systems | 1 | March 10th, 2005 09:30 AM |
| Service Observe with a console? | sjforcum | Definity Servers | 8 | July 18th, 2003 03:04 PM |