Medpro issue

Hey all, I have a strange one. My Medpro board is only showing the "odd" channels. 1-3-5-7. It is an TN2302ap hv21 fw 117 (upgraded to 118). I have moved slots, changed adpt on the rear, even returned the board as defect, new board, same issue. I installed an older Medpro (TN2302ap hv3 fw77) in the same slot and I can see all 8 channels. I am at a loss. Any help is much appreciated.
I am running an s8400 CM 15x.00.0.825.4 w/ patch 00.0.825.4-15759.

On a side note, both the server and CM show no alarms, yet the s8400 blade has the alarm LED lit. ???

Thanks in advance.
phones329 is offline   Reply With Quote
Old June 30th, 2008, 04:19 PM   #2 (permalink)
Lecivius
PBXtech SILVER 25+ posts
 
Join Date: Sep 2007
Posts: 66
Lecivius is on a distinguished road
Re: Medpro issue

The alarm light on the 8400 is a known issue.

As for the Mepro, is it the only one in your Port Network? A bad TDM terminator can cause this issue.
Lecivius is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old July 8th, 2008, 11:38 AM   #3 (permalink)
phones329
PBXtech SILVER 25+ posts
 
phones329's Avatar
 
Join Date: Jul 2003
Posts: 59
phones329 is on a distinguished road
Re: Medpro issue

Yes it is the only one in the PN. I just changed the bus terms to two known good terms and only the odd channels show still.
phones329 is offline   Reply With Quote
Old July 14th, 2008, 04:38 PM   #4 (permalink)
Lecivius
PBXtech SILVER 25+ posts
 
Join Date: Sep 2007
Posts: 66
Lecivius is on a distinguished road
Re: Medpro issue

Ok, changed the terminators & the problem remains. I'm thinking this is a SCC. If so, you may have a bad carrier, or an old one. Have you tried moving the board to another cabinet for testing purposes to see if all the sub processor circuitry is good? And if it tests good, can you provide the J number of the carrier type?
Lecivius is offline   Reply With Quote
Old July 18th, 2008, 05:39 AM   #5 (permalink)
phones329
PBXtech SILVER 25+ posts
 
phones329's Avatar
 
Join Date: Jul 2003
Posts: 59
phones329 is on a distinguished road
Re: Medpro issue

This is a "normal" condition according to Avaya TSO. When I called in for help I was told by Tier 3 that even in thier labs they only see the odd channels on their medpro's.

The cabinet is a CMC. J58890T1L1 (this is only in my lab, actual cust cab is a CMC, but I dont have a J number on it)
phones329 is offline   Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


All times are GMT -6. The time now is 02:08 AM.


Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC6
Copyright ©2002 - 2007, PBXtech LLCAd Management by RedTyger

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38