#1 (permalink) |
![]() Join Date: Aug 2003
Posts: 17
![]() |
LED's on TN464GP
Hello All,I need some assistance. I have been scouring the net and Avaya's website, for information on what the LED's mean on a TN464GP circuit pack. I am hoping with the wonderful knowlegde of this board, someone will be able to help me out. Thanks in advance. Scottie |
|
|
|
|
|
#2 (permalink) |
|
Moderator
![]() Join Date: Jul 2003
Posts: 1,349
![]() ![]() |
Re: LED's on TN464GP
The top three are the same as they are for all Circuit Packs:
Red: Alarm! The system has detected a fault in this circuit pack. The Alarm Log should contain an on-board alarm for this circuit pack or one of the maintenance objects associated with it. The red LED is also lit briefly when a circuit pack is inserted or reset. If the circuit pack passes its initialization tests, the LED is extinguished. If a fault is detected, it remains lit. Green: Testing. The system is currently running tests on this circuit pack as part of background maintenance or demand testing. This LED is also lit briefly during initialization tests when a circuit pack is inserted or reset. Yellow: Busy. The circuit pack is currently in use by the system. The next 4 (Labeled STATUS 1-4) are related to 120A CSU operation. For a complete explanation of their purpose and meaning download the following manual: regs, .al.
__________________
Al Hays, ACE, MCSE, CCNA Homepage: http://www.jeral.com/ Training: http://www.jeral.com/avaya-learning.html |
|
|
|
|