#1 (permalink) |
|
PBXtech GOLD 100+ posts
![]() Join Date: May 2004
Posts: 125
![]() |
How many CLANs - MEDPROs do I need?
I have a definity G3siV11. I have installed IP phones in the LAN working via a specific CLAN - MedPro board. Now I need to administer H323 Trunk via a different router to WAN. Can I use the same CLAN - MedPro boards? And if yes, what gateway will I use for my ip-interfaces?
|
|
|
|
|
|
#2 (permalink) |
|
PBXtech PLATINUM 300+ posts
![]() Join Date: Nov 2004
Posts: 354
![]() |
Re: How many CLANs - MEDPROs do I need?
Information you probably already know, but.... A clan can support up to 400 IP phones but a medpro can only support 64 calls without compression (G.711). If you are using compression then you only get 32 channels.
I am in the process of truning up IP trunking at all my sights. I only have a handfull of IP phones. Regardless, every sight is going to have 2 medpros and 2 to 3 clans. The IP trunks will be configured with 1/2 of the group members using 1 signaling group (clan 1) and the other 1/2 using a different signaling group (clan 2). This was if I loose 1 of the clans only 1/2 of the trunk will go down. Also with 2 medpros you loose 1 you still have 1. I am using G7.11 codec and fully inter-connecting 6 sights with IP trunks. |
|
|
|
|
Advertisement
|
Sponsored links
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Med Pro's without IP why??? | danno | Definity Servers | 12 | April 6th, 2005 02:17 PM |
| CM2.1 and Medpros | stubborne | Definity Servers | 4 | March 28th, 2005 08:39 AM |
| FYI- Clans don't play well | technician101 | Definity Servers | 3 | May 26th, 2004 02:23 PM |