Old August 10th, 2005, 09:52 AM   #1 (permalink)
nstephens8
PBXtech SILVER 25+ posts
 
nstephens8's Avatar
 
Join Date: Feb 2005
Posts: 48
nstephens8 is on a distinguished road
Question s8700MS IP Signaling test

I am trying to get an IP trunk set up and after getting the ip-routes set up, the signaling group will not come up. I did a test on the signaling group and encountered a FAIL.

Port Maintenance Name Alt. Name Test No. Result Error Code

36 H323-SGR 1386 FAIL 1
36 H323-SGR 1392 PASS
36 H323-SGR 1387 PASS

Does anybody know what the 1386 failure is?

Thanks
nstephens8 is offline   Reply With Quote
Old August 10th, 2005, 11:40 AM   #2 (permalink)
liquidvw
PBXtech PLATINUM 300+ posts
 
Join Date: Nov 2004
Posts: 354
liquidvw is on a distinguished road
Re: s8700MS IP Signaling test

Yea I found that one.

Test 386 error 1. Represents a failure of the clan hardware carrying the signaling group D channel. Check the errors against the clan bd maintenance object.

What happens when you status the singaling group on each end?
liquidvw is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Old August 10th, 2005, 02:40 PM   #3 (permalink)
nstephens8
PBXtech SILVER 25+ posts
 
nstephens8's Avatar
 
Join Date: Feb 2005
Posts: 48
nstephens8 is on a distinguished road
Re: s8700MS IP Signaling test

The signaling group on the near end reports out of service.

The far end...in service.

I did a test on the C-Lan and an ABORT occurred. Any ideas?


TEST RESULTS

Port Maintenance Name Alt. Name Test No. Result Error Code

01A12 CLAN-BD 52 PASS
01A12 CLAN-BD 598 PASS
01A12 CLAN-BD 600 PASS
01A12 CLAN-BD 601 PASS
01A1217 ETH-PT 1281 ABORT 0
01A1217 ETH-PT 1286 PASS
01A1217 ETH-PT 1282 PASS
01A1217 ETH-PT 1511 PASS
nstephens8 is offline   Reply With Quote
Old August 10th, 2005, 03:20 PM   #4 (permalink)
liquidvw
PBXtech PLATINUM 300+ posts
 
Join Date: Nov 2004
Posts: 354
liquidvw is on a distinguished road
Re: s8700MS IP Signaling test

1281 looks like a ping test. Can you ping the clan from your PC or from another PBX?

Take a look at stat clan-port 01a1217. The clan might not be enabled or busyed.
liquidvw is offline   Reply With Quote
Old August 11th, 2005, 02:59 PM   #5 (permalink)
nstephens8
PBXtech SILVER 25+ posts
 
nstephens8's Avatar
 
Join Date: Feb 2005
Posts: 48
nstephens8 is on a distinguished road
Re: s8700MS IP Signaling test

Thanks liquid...

What is strange, now that I have taken the signaling group and moved it to my secondary CLAn, the CLAN in question tests fine.

I noticed that the install team has the CLAN set with Ethernet Option of Auto.

I am thinking I may want to hard code the Cisco and CLAN to Full/100.

Any thoughts?

My CLAN in another switch (G3Si V2.1) has the CLAN set to Half/10.

Should I just set to Half/10, full/100 or keep it auto?
nstephens8 is offline   Reply With Quote
Old August 12th, 2005, 11:57 AM   #6 (permalink)
liquidvw
PBXtech PLATINUM 300+ posts
 
Join Date: Nov 2004
Posts: 354
liquidvw is on a distinguished road
Re: s8700MS IP Signaling test

Depends. The PBX setting must match your LAN switch. If there is a mismatch. ie PBX auto, LAN 10/half (or something like that) you will have problems. I allways have my Clan set to 100 full and the LAN switch set to 100 full. Once I have a mismatch, it caused some wired problems.
liquidvw is offline   Reply With Quote
Advertisement
 
Advertisement
Sponsored links

Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
ISDN BRI signaling link down ruudsplint Definity Servers 2 November 25th, 2005 01:35 AM
Signaling question George V. Definity Servers 0 November 16th, 2004 01:11 PM
IP Telephony Design Elective Test defh Avaya Certifications - no cheat sheet here 1 November 10th, 2004 05:26 PM
Test Station Error Codes ronarn Definity Servers 1 July 16th, 2004 01:01 PM
Signaling Test on a Digital Telephone Andrew Meridian systems 0 July 9th, 2003 09:36 AM


All times are GMT -6. The time now is 07:49 AM.


Powered by vBulletin® Version 3.7.2
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC6
Copyright ©2002 - 2007, PBXtech LLCAd Management by RedTyger

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37