#1 (permalink) |
![]() Join Date: Jul 2005
Posts: 1
![]() |
Problem with static on DS1 configured as T1 robbed-bit
Hello. I am new to this forum and am an amateur Avaya tech for my company. We have a few DS1 boards on our Avaya G3si that we use to connect to IVR systems. Two of the DS1s are TN464E boards and one is a TN767E board. I have configured all of the boards as follows:
ami-basic d4 robbed-bit mulaw No slip detection and have assigned OPS extensions to all of the channels. When I place a call to one of the assigned extensions, my IVR answers but the circuit immediately goes into a Yellow Alarm and I hear crackling on the line. These circuits used to work with my IVR systems, and the IVR systems work with T1 circuits from other switches (Siemens). Somehow, I must have changed some configuration setting in the switch, but I cannot figure out what I did. I recently replace the Tone Clock card thinking I may have a clocking problem. I also tried to change the boards for the system synchronization but get the same results. Does anybody have any suggestions on how I can correct this problem? Thanks in advance. |
|
|
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| What's the diff between a T1 and a DS1 | fataldata | The Lounge | 11 | March 9th, 2006 03:23 PM |
| Problem with advice of charge on DS1 | iacovides | Definity Servers | 8 | December 14th, 2005 07:59 AM |