Re: E-911 setup
We have a G3R V6.3 and in addition to using a 3rd party database (Red Sky) installed on a stand-alone PC (non-network), we have to increment the "Site Data" section on page 3 of station forms. You have to fill in room, floor and building minimally, We have given the Red Sky software a "browse" only login to the G3R and it builds a data base and uploads it to SBC's 911 center via a modem.
|
|
|
|
|