Quote:
Originally Posted by stubborne
Where did you make this change? I'm trying to understand how it fixed your issue. We have some PRIs to a DMS100 type switch that are having call quality issues. After a period of time, the call will degrade where the far end hears bursts of static while our PBX callers hear dead-air. Any help or more info would be beneficial - thanks!
Sorry for the delay in response (I took a mini-vacation). The change I made was the Service Type on the first page of the trunk-group configuration. Among the possible choices are public-ntwrk, operator, dmi-mos, access, accunet, ...).

The other piece was figuring out which ds1 protocol worked with the service provider's set-up. The Protocal Type (a,b,c, or d) is under the ds1 configuration.