Quote:
|
Originally Posted by crookie
Can anyone help?
I am having a problem with a 406 resetting intermittently.
The error I get is :
22873466mS PRN: .FATAL TLB Data Error address=aaaaaaaa d=5 pc=015a8204 00000000 015a82c8 015b02a8 017ebeb4 017ea9f4 IP 406 2.1(15)
The cpu has been changed along with the PRI.There has been a manual retype.
The system has been disconnected from the network. BT Have checked the lines. System been upgraded to 2.1.
Any help would be welcome.
|
If it's still resetting after being disconnected from the network, it's not malware doing a DoS attack. You've changed the CPU and reprogrammed the config from scratch? I would copy and paste that error into an email and send it to your distributor (or whoever your official avaya tech support is) and have them escalate it up the chain until someone can say exactly what that error means. Even if it has to go WAYYY over the cold deep waters until it comes to a drearly little island off the coast of europe where various IP gurus and their faithful adherrents are reputed to live.... :D