Re: track spare phones left on desk
TTI tracks Site Data based on the circuit pack port. If a station is TTI'd off one port and onto another it assumes the Site Data of the new port AND the site data from the old port will be assigned to the next station to be TTI'd to that port.
Try using ASA to run a report and save as a delimited file, bring into Excel or Access and verify current site data. Make it the way you want. Stations can then be updated using Excel and ASA Import.
Once you have all ports/stations with valid Site Data, turn TTI off in system features, then status tti repeatedly until 100% off. Then turn it back on and again status until 100%. Now you have valid Site Data on all connected ports. Next time you move a jumper or install/remove a circuit pack, turn TTI off before making the change/addition and turn back on afterwards.
I presented this at INAAU in Seattle a few years ago. If you have specific problems, send me a personal message on this site, I'll get in touch w/you.