View Single Post
Old January 18th, 2008, 01:38 PM   #3 (permalink)
techma
PBXtech SILVER 25+ posts
 
Join Date: Jul 2007
Posts: 88
techma is on a distinguished road
Re: Duplicated Si R8

This happens to be an Si running in a refrigerator cabinet and only the boards were changed out. There's a TN790B, TN792, 794/2400 and those were the only boards switched out. No other changes were made to the switch. I recently discovered that one of the Emergency Transfer switches on one of the processors was set to "OFF". Would that cause it to not answer when it the SPE is interchanged to "B"?
techma is offline   Reply With Quote