View Single Post
Old December 17th, 2007, 05:55 PM   #1 (permalink)
phones329
PBXtech SILVER 25+ posts
 
phones329's Avatar
 
Join Date: Jul 2003
Posts: 59
phones329 is on a distinguished road
IPSI/SIPI Aux pwr

I am wondering about Aux pwr from an IPSI/SIPI. I know you can get one pair of Aux pwr to support the console. I tried to hook up a second lead for a Univ 909, but it would not work. I have 47.8 volts on pairs 1,2 and 4, but am only able to make something work on pair 1 (bl)

If I put the Univ 909 on the first pair it worked, and if I moved the console to anoher pair it did not. Can the IPSI/SIPI only support one pair even though there is voltage on the other pairs?

Any help is appreciated. Thanks!
phones329 is offline   Reply With Quote