Re: TN767E default settings to emulate T1

I got him to fax me a display print of what he has
bit rate: 1.544
line compensation: 1
signaling mode: robbed-bit
idle code: 11111111
line coding: b8zs
framing mode: esf
slip detection: n
CSU type: integrated
net management protocol: tabs
performance reports: n
Farend csu address: b
transmit: .0db
receive: 26db
upon DTE LOS: loopback
loopback jack power: n

Some of these settings make a little bit of sense from the PDF G3V3 Addendum 2 to AT&T 555-230-653 I've been reading. With those settings listed above do you think I would need to go to his telco provider to find out what they would be sending and need from the Dialogic card in order to answer or is the Definity still doing some type of managing of the call coming to the Dialogic card? I will see if I can have him do the "display port" command also.