Re: Limitations of Definity Prologix

No, you do not need a Call Classifier in cabinet C. You only need one per port network and a Prologix is only one port network.

You said you tested the slots with a known good TN2793 and it also alarmed. When you returned it to the slot it came from, was it ok? I am still inclined to believe you have a physical problem with cabinet C itself. Perhaps bent pins that don't become live until a 24 port card is inserted. Take a flashlight and look at the back plane for the slots in question.

Also, the new boards that alarmed, did you try them in a slot that already has a TN2793 in it?